Temperature data logger with bendable semi-rigid probe up to 250°C provided with Accredia traceable certificate

S-MicroW L Bendable is a temperature data logger from -40°C to 250°C (calibration from 25°C to 140°C, calibrable from -40°C up to 250°C, above 140°C the probe only resists) with 30 cm bendable probe and 50 mm or on demand length external probe (probes cannot be switched) on a 5 mm base (base height is not counted for probe length), managed with Windows software and USB interface (DiskInterface HS, Multibay). Battery is user replaceable and the data logger is provided with an Accredia (NIST equivalent) traceable cetificate on 6 points.

The other versions of the data logger are:

  • S-MicroW L: with rigid probe of different lengths
  • S-MicroW L Flexible: with flexible cable probe and rigid probe at the end
  • S-MicroW L Ultra Freeze: includes calibration points from -40°C for use also from -80°C

For each version it is available the XL model too, S-MicroW XL Bendable, which has same diameter but is higher because it hosts a bigger battery for a longer life time.

There are also other models of high temperature data loggers, for pressure and humidity too.

Note: if used below -30°C, battery life will be highly reduced.

Video

Applications

Main features

  • With bendable cable to place the device near the packages instead on top and with rigid probe for penetration
  • Completely food grade and waterproof
  • All software calculate lethality value (F0, PU, A0 ecc.)
  • Low battery consumption for an extended battery life
  • User replaceable battery (software shows battery status)
  • Very easy to deploy in any type of package
  • Accredia (NIST equivalent) traceable calibration certificate included
  • Available extended calibration from -40°C to 250°C (order extra calibration points; in case of wide calibration range the accuracy might be worse. Request the possible calibration ranges in advance)

Plus

  • Extremely high accuracy and precision: with an accuracy of ± 0,1°C these devices can be employed in any application involving pharmaceuticals, validation, laboratory and medical field
  • High accuracy even outside the calibration range
  • Fast response time thanks to the 3 mm diameter probe
  • Easy to use even in small and narrow places thanks to the bendable probe
  • Printed reports compliant with health regulations and ISO (data are not editable in the software)

The system

The system is made up by:

  • S-MicroW L temperature data logger
  • DiskInterface HS or Universal Multibay
  • SPD software or TS Manager software (compatible with the FDA 21 CFR Part 11 regulation)

Dimensions 39 h X 20 Ø (mm)
Probe dimensions Probe base dimensions 5 h X 14 Ø (mm) - Bendable probe 300 l X 2 Ø (mm) - Rigid probe base dimensions 5 h X 5,5 Ø (mm) - Probe 50 l X 3 Ø (mm) - Probe l on demand X 3 Ø (mm) (l on demand: min. 10 mm / max. 175 mm. For longer probes ask for quotation)
Weight 50 gr
Materials Stainless steel AISI316L, PEEK
Temperature range -40°C ÷ +140°C
Sensor temperature range -40 °C ÷ +250 °C
Standard calibration points (temperature) 25/50/75/100/125/140°C
Extra calibration points (temperature) Within the range -40 °C ÷ +250 °C
Temperature resolution 0,01 °C
Temperature accuracy ± 0,1 °C (within the calibration range)
Memory (n. of acquisitions) 20.224
Acquisition step From 1 every second up, with 1 second steps
Protection degree IP68
Battery life +10.000.000 acquisitions at 1 second step continuously (calculated time @25°C. Battery life may be shorter if used in low temperatures)
Software&Mobile App SPD, TS Manager
Accessories DiskInterface HS, Multibay universale

Documentation

You may also be interested in...