Subscribe to our newsletter - Tech support

Pressure data logger for vacumm in plasma autoclaves

A pressure data logger for plasma (hydrogen peroxide) autoclaves and very low temperature and extreme vacuum freeze drying processes with very high features. This is the version with a ½ Gass thread for external mount on autoclaves.

Two combined sensors, one for extreme vacuum and one for higher pressures, up to 1200 mbar allow to obtain an incredible accuracy of ±0.0003 and a resolution of 0,0001 mbar.

The software is Windows based and communicates by means of a USB interface (DiskInterface HS). Battery is user replaceable and the data logger is provided with an Accredia (NIST equivalent) traceable certificate on different points.

Download

DiskInterface HS, DiskInterface HS Mini - USB drivers Windows 8 / 10

Software download and related accessories

Applications

Main features

  • Resists up to 85°C
  • Available in two versions: standard and with ½ Gass threaded connector
  • Temperature channel with internal sensor for testing
  • Low battery consumption for an extended battery life
  • User replaceable battery (software shows battery status)
  • Reference traceable calibration certificate included
  • Available extended calibration from -60°C (order extra calibration points)

Plus

  • Extremely high accuracy and precision in extreme vacuum
  • Easy to use
  • Battery with extremely extended life
  • Printed reports compliant with health regulations and ISO (data are not editable in the software)

The system

The system is made up by:

  • Pirani Vacuum Logger pressure data logger
  • DiskInterface HS
  • TS Manager or HumiPressureDisk software
Dimensions 84 h X 30 Ø (mm) - 31 Ø (mm) PEEK ring
Weight 160 g
Materials Stainless steel AISI316L, PEEK
Temperature range -80 °C ÷ +85 °C
Standard calibration points (temperature) 0/25/50/75°C
Extra calibration points (temperature) Range -80°C ÷ + 85°C
Temperature resolution 0,01 °C
Temperature accuracy ± 0,1 °C from 0 °C to +85 °C
Pressure range 0,001 mbar ÷ 1200 mbar absolute
Standard calibration points (pressure) 2.0 e¯³ / 5.0 e¯³ / 2.0 e¯² / 5.0 e¯² / 2.0 e¯¹ / 5.0 e¯¹ / 2 / 5 / 25 / 50 / 300 / 500 / atmospheric pressure mbar @ 20°C / t. amb. (25°C +/-10°C) / 50°C / 80°C
Extra calibration points (pressure) Within the range 0.01 mbar ÷ 1200 mbar absolute
Pressure resolution 0,0001 mbar
Pressure accuracy ± 0,0005 (0,001 ÷ 0,005) / ± 0,0003 (0,005 ÷ 0,01) / ± 0,01 (0,01 ÷ 0,1) / ± 0,05 (0,1 ÷ 0,5) / ± 0,1 (0,5 ÷ 1) / ± 0,5 (1 ÷ 5) / ± 2 (5 ÷ 100) / ± 3 (100 ÷ 500) / ± 5 (500 ÷ 1000); all values in mbar
Memory (n. of acquisitions) 43.690
Acquisition step From 1 every second up
Battery life +19.000.000 acquisitions at 1 second step continuously (calculated time @25°C. Battery life may be shorter if used in low temperatures)
Accessories DiskInterface HS

Documentation

Faq

You may also be interested in...